Master Chef E500 Bedienungshandbuch Seite 7

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 22
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 6
5
Propane Models:
Your Barbecue is designed to operate on L.P gas at a pressure of 2.74Kpa (11” water column). A regulator preset to this
pressure is supplied with your Barbecue.
QCC-1 Quick Closing Coupling
All models are designed to be used with an LP gas cylinder equipped with the
new QCC-1 Quick Closing Coupling system.
The QCC-1 system incorporates new safety features required by the Canadian
Standards Steering Committee.
• Gas will not ow until a positive connection has been made
• A thermal element will shut o the ow of gas between 240 degrees and
300 degrees F.
When activated, a Flow Limiting Device will limit the ow of gas to 10 cubic
feet per hour.
Connecting Regulator to the LP Cylinder
1. LP cylinder must be properly secured onto grill.
2. Turn all control knobs to the “OFF” position.
3. Turn LP cylinder “OFF” by turning hand-wheel clockwise to a full stop.
4. Remove the protective cap from LP cylinder valve. Always use cap and strap
supplied with valve.
5. Hold regulator and insert nipple into LP cylinder valve. Hand tighten the
coupling nut. Hold the regulator in a straight line with LP cylinder valve so
as not to cross-thread the connection.
6. Turn the coupling nut clockwise and tighten to a full stop. The regulator will seal
on the back-check feature in the LP cylinder valve, resulting in some resistance.
NOTE:
If you cannot complete the connection, disconnect regulator and repeat
steps 5 and 6. If you are still unable to complete the connection, do not
use this regulator!
DANGER
Do not insert any tool or foreign object into the valve outlet or safety relief valve. You may damage the
valve and cause a leak. Leaking propane may result in explosion, re, severe personal injury, or death.
1. Turn all grill control knobs to OFF”.
2. Ensure that the regulator is tightly connected to LP cylinder.
3. Completely open LP cylinder valve by turning hand wheel counterclockwise.
If you hear a rushing sound, turn gas o immediately. There is a leak at the
connection. Correct before proceeding.
4. Brush soapy solution onto hose and regulator and all connections from the
LP tank to the main and side burner manifold.
5. If growing” bubbles appear, there is a leak. Close LP cylinder valve
immediately and re-tighten connections. If leaks cannot be stopped do
not try to repair. Call for replacement parts. Order new parts by providing
the serial number, model number, name and part number of items required
(see parts list) to a Customer Care Agent 1-855-453-2150.
6. Always close LP cylinder valve after performing leak test by turning hand wheel clockwise.
SAFETY HOSE AND REGULATOR
LEAK TESTING THE VALVE, HOSE AND REGULATOR ASSEMBLY
Hold coupling nut and
regulator as shown for
proper connection to
LP cylinder valve.
Nipple has to be centered
into the LP cylinder valve.
Regulator
Heat sensitive hand wheel
Nipple with ow limiting device
Shut o valve
Check valve